Ametek BPS Series Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Ametek BPS Series. AMETEK BPS Series User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 153
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - User Manual

M440077-01 Rev A www.programmablepower.com BPS Series AC Power Source User Manual

Strona 2

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 10 List of Tables Table 3-1:

Strona 3 - BPS Series User Manual

User Manual AMETEK Programmable Power BPS Series 100 5.4.4.3 Trigger delay The trigger delay field allows the user the set the amount of pre- o

Strona 4

User Manual AMETEK Programmable Power BPS Series 101 PRE TRIGGER DELAY Alternatively, a negative trigger delay value may be specified up to the

Strona 5 - PRODUCT RETURN PROCEDURE

User Manual AMETEK Programmable Power BPS Series 102 5.5 Transient Programming 5.5.1 Introduction Transient programming provides a precise tim

Strona 6 - Table of Contents

User Manual AMETEK Programmable Power BPS Series 103 5.5.4 Pulse Transients Pulse transients let you program the output to a specified value fo

Strona 7

User Manual AMETEK Programmable Power BPS Series 104 5.5.5 List Transients List transients provide the most versatile means of controlling the

Strona 8

User Manual AMETEK Programmable Power BPS Series 105 9. Move the cursor to the GO TO VOLT field and enter 160.0 10. Move the cursor to the DUR

Strona 9 - List of Figures

User Manual AMETEK Programmable Power BPS Series 106 Note: The AC source output remains at the last programmed values at the completion of the

Strona 10 - List of Tables

User Manual AMETEK Programmable Power BPS Series 107 5.5.7 Transient Execution Figure 5-30: START/VIEW TRANSIENT SEQUENCE Menu A transient li

Strona 11 - 1. Introduction

User Manual AMETEK Programmable Power BPS Series 108 6. Principle of Operation 6.1 General An explanation of the circuits in the BPS Series is

Strona 12 - 2. Specifications

User Manual AMETEK Programmable Power BPS Series 109 6.2 Overall Description Three-phase input power is routed from the back of the cabinet to

Strona 13 - < 20 mV

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 11 1. Introduction This instru

Strona 14

User Manual AMETEK Programmable Power BPS Series 110 6.3 Controller Assembly The Controller Assembly is located in the top section of the BPS u

Strona 15

User Manual AMETEK Programmable Power BPS Series 111 Figure 6-2: BPS90 Series Detailed Block Diagram

Strona 16

User Manual AMETEK Programmable Power BPS Series 112 Figure 6-3: Power Module Detailed Block Diagram

Strona 17 - 2.2 Mechanical

User Manual AMETEK Programmable Power BPS Series 113 6.4 System Interface Board The System Interface Board is located in the top section of the

Strona 18 - 2.5 Front Panel Controls

User Manual AMETEK Programmable Power BPS Series 114 Figure 6-4: Power Module Layout

Strona 19

User Manual AMETEK Programmable Power BPS Series 115 6.7.1 PFC Input Power Converter The PCF section is located at the bottom of each power mod

Strona 20

User Manual AMETEK Programmable Power BPS Series 116 6.7.3 Amplifier Boards The Amplifier boards are each attached to a heat sink and stacked o

Strona 21 - Current

User Manual AMETEK Programmable Power BPS Series 117 6.7.4 Filter Boards A set of two identical inductor boards is located behind the Modulator

Strona 22

User Manual AMETEK Programmable Power BPS Series 118 CAUTION VOLTAGES UP TO 480 VAC AND 450 VDC ARE PRESENT IN CERTAIN SECTIONS OF THIS P

Strona 23 - 3.2 Power Requirements

User Manual AMETEK Programmable Power BPS Series 119 7. Calibration The Routine Calibration should be performed every 12 months. Non-routine C

Strona 24 - 3.3 Mechanical Installation

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 12 2. Specifications Specifica

Strona 25 - Front View, Panel Removed

User Manual AMETEK Programmable Power BPS Series 120 7.2 Front Panel Calibration Screens The calibration screens for output or measurement cali

Strona 26

User Manual AMETEK Programmable Power BPS Series 121 Figure 7-1: Sample Voltage Calibration Setup BPS75 or BPS90 (Rear view) 7.3 Routine Measu

Strona 27 - AC Line

User Manual AMETEK Programmable Power BPS Series 122 Note: The Agilent 3458A Digital Multimeter or equivalent must be used for the following c

Strona 28

User Manual AMETEK Programmable Power BPS Series 123 Figure 7-2: Sample BPS 90 Current Measurement Calibration Setup (Rear view)

Strona 29

User Manual AMETEK Programmable Power BPS Series 124 Connect the load to the output. Use the 1 mOhm current shunt in series with the load to m

Strona 30 - 3.6 Output Connections

User Manual AMETEK Programmable Power BPS Series 125 7.3.1 Measurement Cal - AC To calibrate AC measurements, set the power source to the AC m

Strona 31

User Manual AMETEK Programmable Power BPS Series 126 7.4 Routine Output Calibration For best results, it is recommended to perform the measurem

Strona 32

User Manual AMETEK Programmable Power BPS Series 127 7.4.1 Output Cal 300 VAC Range DC Zero: Program the output to the 300 VAC Range by pres

Strona 33 - BPS30-1 or BPS45-1

User Manual AMETEK Programmable Power BPS Series 128 7.4.2 Three Phase Mode As indicated earlier, for 3-Phase power system (BPS30-3, BPS45-3, B

Strona 34

User Manual AMETEK Programmable Power BPS Series 129 7.5 Non-Routine Calibration WARNING: THIS EQUIPMENT GENERATES POTENTIALLY LETHAL VOLTA

Strona 35

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 13 2.1.2 Output Note: All spe

Strona 36

User Manual AMETEK Programmable Power BPS Series 130 7. Move the DMM leads to the C module terminals 6 and 7 in the auxiliary cabinet. Press th

Strona 37 - 4.3 Mechanical Installation

User Manual AMETEK Programmable Power BPS Series 131 8. Service 8.1 Cleaning The exterior of the power source may be cleaned with a cloth damp

Strona 38

User Manual AMETEK Programmable Power BPS Series 132 8.3.3 Overload Light is On CAUSE SOLUTION Unit is overloaded Remove overload or check CL

Strona 39

User Manual AMETEK Programmable Power BPS Series 133 8.4 Advanced Troubleshooting. WARNING: Do not connect 400-480V into the 208-240V unit,

Strona 40

User Manual AMETEK Programmable Power BPS Series 134 8.4.5 Power-on Troubleshooting Using the LED’s. WARNING: Do not touch any parts inside

Strona 41

User Manual AMETEK Programmable Power BPS Series 135 PFC failure denotes one or all three of the IGBT power modules on the large PFC heat sink h

Strona 42 - 4.6 Output Connections

User Manual AMETEK Programmable Power BPS Series 136 8.6 Fuses FUSE # FUNCTION FUSE VALUE CI # F1 thru F6 AC mains input, 208 - 240V. 200

Strona 43

User Manual AMETEK Programmable Power BPS Series 137 8.7 Firmware Updates All BPS Series units support firmware updates over the RS232C interfa

Strona 44

User Manual AMETEK Programmable Power BPS Series 138 Power up the AC source using its on/off switch. A message will appear on the LCD once the p

Strona 45

User Manual AMETEK Programmable Power BPS Series 139 Click on the “Init Port” button. If the selected port can be initialized, the “Flash Update

Strona 46

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 14 Output Parameter BPS30 BPS

Strona 47

User Manual AMETEK Programmable Power BPS Series 140 9. Top Assembly Replaceable Parts – BSP30 and BPS45 Models Note that different generation

Strona 48 - 4.7 Connectors - Rear Panel

User Manual AMETEK Programmable Power BPS Series 141 Ref. CI P/N Description Vendor Qty Location K3 245248 Relay, 3C, 100A, 24VDC ABB AF75

Strona 49

User Manual AMETEK Programmable Power BPS Series 142 Seq # CI P/N Description Vendor Qty Assy. Number and Location Top Assembly 7003-400-01

Strona 50

User Manual AMETEK Programmable Power BPS Series 143 10. Top Assembly Replaceable Parts – BPS75, BPS90, BPS150 and BPS180 Models. Note that dif

Strona 51

User Manual AMETEK Programmable Power BPS Series 144 Ref. CI P/N Description Vendor Qty Location Amplifier Assy. 15Kva 7003-433-5 A1 7003-7

Strona 52

User Manual AMETEK Programmable Power BPS Series 145 11. Options 11.1 Introduction There are a number of options available for the BPS Series,

Strona 53

User Manual AMETEK Programmable Power BPS Series 146 12. Error Messages Any errors that occur during operation from either the front panel or t

Strona 54

User Manual AMETEK Programmable Power BPS Series 147 Number Message String Cause Remedy DC mode. -201 "Invalid while in local" Co

Strona 55

User Manual AMETEK Programmable Power BPS Series 148 Number Message String Cause Remedy downloading waveform again. Successful download may c

Strona 56

User Manual AMETEK Programmable Power BPS Series 149 Number Message String Cause Remedy configuration data. 7 "System memory lost"

Strona 57

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 15 Figure 2-1: Sample BPS9

Strona 58 - 5. Front Panel Operation

User Manual AMETEK Programmable Power BPS Series 150 Number Message String Cause Remedy closed. is physically disconnected during voltage ra

Strona 59

User Manual AMETEK Programmable Power BPS Series 151 Index ++/- key ... 62 AAC inp

Strona 60

User Manual AMETEK Programmable Power BPS Series 152 MEAS key ... 61 measurement calibratio

Strona 61 - FUNCTION

User Manual AMETEK Programmable Power BPS Series 153 waveform group ... 88 Weight ...

Strona 62

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 16 2.1.4 System Specification

Strona 63

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 17 2.1.5 Unit Protection Input

Strona 64

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 18 2.3 Environmental Parameter

Strona 65 - 5.2 Menu Structure

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 19 Displays: LCD graphics displ

Strona 66

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 2 User Manual California Instru

Strona 67 - 5.2.2 Overview of Menu 1

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 20 2.6.1 -HV Option Specificat

Strona 68 - BPS Series 68

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 21 Figure 2-2: Sample BPS90 Vo

Strona 69 - Figure 5-8: PROGRAM Menu

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 22 2.6.2 -LF Option Specifica

Strona 70

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 23 3. Unpacking and Installati

Strona 71

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 24 3.3 Mechanical Installation

Strona 72

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 25 Figure 3-2: Location of BPS

Strona 73 - Figure 5-10: TRANSIENTS Menu

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 26

Strona 74

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 27 Figure 3-3: BPS30 and BPS45

Strona 75

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 28 The input power cables and p

Strona 76

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 29 Note: Under no circumstance

Strona 77

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 3 About AMETEK AMETEK Programma

Strona 78

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 30 3.6 Output Connections 3.6.

Strona 79

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 31 be a function of the voltage

Strona 80

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 32 3.6.2 Output Terminal Block

Strona 81

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 33 3.6.3 BPS30-1, BPS45-1 - 1

Strona 82 - Figure 5-17: UTILITY Menus

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 34 3.6.4 BPD30-3, BPS45-3 3ø

Strona 83

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 35 4. Unpacking and Installati

Strona 84

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 36 Figure 4-1: BPS75/BPS90 Pow

Strona 85

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 37 4.3 Mechanical Installatio

Strona 86

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 38 Figure 4-2: Location of BPS

Strona 87

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 39 Figure 4-3: BPS75-3 or BPS9

Strona 88

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 4 Important Safety Instruction

Strona 89

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 40 The input power cables and p

Strona 90

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 41 CAUTION: The AC input fuse

Strona 91

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 42 4.6 Output Connections 4.6.

Strona 92

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 43 Cable lengths must not excee

Strona 93 - 5.3 Output Programming

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 44 4.6.2 Output Terminal Block

Strona 94 - 5.4 Standard Measurements

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 45 4.6.3 Output Wiring Diagra

Strona 95

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 46 4.6.4 BPS150-3 or BPS180-3 Para

Strona 96

User Manual AMETEK Programmable Power BPS Series 47 4.6.5 Multi-Chassis Output Connections If two or more BPS chassis are used to form a single

Strona 97

User Manual AMETEK Programmable Power BPS Series 48 4.7 Connectors - Rear Panel A number of connectors are located along the center rear panel.

Strona 98

User Manual AMETEK Programmable Power BPS Series 49 P8 / P9 Description 26 CLA: Current Limit A. Programmed current limit reference for phas

Strona 99

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 5 Product Family: BPS Series A

Strona 100

User Manual AMETEK Programmable Power BPS Series 50 4.7.3 BNC Connectors BNC connectors. Functions are called out on rear panel decal. Table sh

Strona 101

User Manual AMETEK Programmable Power BPS Series 51 4.7.5 RS232C Serial Interface Connector An RS232 serial interface connector is located on t

Strona 102 - 5.5 Transient Programming

User Manual AMETEK Programmable Power BPS Series 52 4.7.6 USB Interface A standard USB Series B device connector is located on the rear panel f

Strona 103

User Manual AMETEK Programmable Power BPS Series 53 4.7.7 LAN Interface – RJ45 An optional RJ45 Ethernet 10BaseT connector is located on the re

Strona 104 - Figure 5-29: List Transients

User Manual AMETEK Programmable Power BPS Series 54 4.8 Multiple Cabinet Power Up/Down Procedures For all multi-cabinet BPS Series configurati

Strona 105

User Manual AMETEK Programmable Power BPS Series 55 4.9 Basic Initial Functional Test CAUTION: Work carefully when performing these tests;

Strona 106

User Manual AMETEK Programmable Power BPS Series 56 Figure 4-11: Functional Test Setup. 4.10 Remote Inhibit / Remote Shutdown It may be necess

Strona 107

User Manual AMETEK Programmable Power BPS Series 57 It is possible to reverse the polarity of the RI input. This requires the use of the followi

Strona 108 - 6. Principle of Operation

User Manual AMETEK Programmable Power BPS Series 58 5. Front Panel Operation 5.1 Tour of the Front Panel The BPS Series controllers have ident

Strona 109 - 6.2 Overall Description

User Manual AMETEK Programmable Power BPS Series 59 5.1.3 Status Indicator Lights Four LED status indicators are located directly above the mai

Strona 110 - 6.3 Controller Assembly

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 6 Table of Contents 1. Introd

Strona 111 - BPS Series 111

User Manual AMETEK Programmable Power BPS Series 60 5.1.4 The Shuttle Knob CounterClockwiseClockwiseINCRDECR Figure 5-1: Shuttle Knob The shutt

Strona 112

User Manual AMETEK Programmable Power BPS Series 61 5.1.5 FUNCTION Keypad The function keypad provides access to all menus and measurement scre

Strona 113 - 6.7 Power Module

User Manual AMETEK Programmable Power BPS Series 62 OUTPUT ON/OFF The OUTPUT ON/OFF key toggles the output relay on or off. The state of the ou

Strona 114 - BPS Series 114

User Manual AMETEK Programmable Power BPS Series 63 5.1.6 DECIMAL KEYPAD The decimal keypad may be used to enter any numeric parameter required

Strona 115

User Manual AMETEK Programmable Power BPS Series 64 Figure 5-5: Cursor DOWN key Movement The decimal keypad can be used at any time in lieu of

Strona 116

User Manual AMETEK Programmable Power BPS Series 65 5.2 Menu Structure The next few pages show a map of the available menus in the BPS Series.

Strona 117

User Manual AMETEK Programmable Power BPS Series 66 The following top-level menu choices can be accessed from the MENU key: Entry Description

Strona 118 - CAUTION

User Manual AMETEK Programmable Power BPS Series 67 5.2.2 Overview of Menu 1 level 1 level 2 level 3 MENU 1 PROGRAM PROGRAM1 V

Strona 119 - 7. Calibration

User Manual AMETEK Programmable Power BPS Series 68 5.2.3 Overview of Menu 2 and 3 level 1 level 2 level 3 MENU 2 ADVANCE HARMONICS/TR

Strona 120

User Manual AMETEK Programmable Power BPS Series 69 PHASE OFST IHARM FS IMP. REAL FS IMP. REACT FS IMP.

Strona 121

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 7 4.9 Basic Initial Functional

Strona 122

User Manual AMETEK Programmable Power BPS Series 70 PROGRAM 2 PHASE Selects the phase angle between the external clock and the output of the A

Strona 123 - BPS Series 123

User Manual AMETEK Programmable Power BPS Series 71 5.2.5 MEASUREMENTS Screens The BPS Series uses a DSP based data acquisition system to provi

Strona 124

User Manual AMETEK Programmable Power BPS Series 72 MEASUREMENT 3 VOLT THD This readout displays the total voltage distortion for the selected

Strona 125

User Manual AMETEK Programmable Power BPS Series 73 5.2.6 TRANSIENTS Menu Figure 5-10: TRANSIENTS Menu The transient menu provides access to

Strona 126

User Manual AMETEK Programmable Power BPS Series 74 5.2.6.1 VOLT SURGE/SAG sub menu Figure 5-11: VOLTAGE SURGE/SAG SETUP Screen The Voltage su

Strona 127

User Manual AMETEK Programmable Power BPS Series 75 REPEAT This is the number of times the SURGE/SAG transient event will repeat before it will

Strona 128 - 150 VAC range, 120V

User Manual AMETEK Programmable Power BPS Series 76 5.2.6.2 VOLTAGE SWEEP/STEP sub menu Figure 5-12: VOLTAGE SWEEP/STEP SETUP Screen The Volta

Strona 129

User Manual AMETEK Programmable Power BPS Series 77 EVENT # This must be the last item in the transient edit screen. All data fields must be en

Strona 130

User Manual AMETEK Programmable Power BPS Series 78 5.2.6.3 FREQUENCY SWEEP/STEP sub menu Figure 5-13: FREQUENCY SWEEP/STEP SETUP Screen The V

Strona 131 - 8. Service

User Manual AMETEK Programmable Power BPS Series 79 5.2.6.4 VOLTAGE/FREQUENCY SWEEP/STEP sub menu Figure 5-14 VOLTAGE/FREQUENCY SWEEP/STEP SE

Strona 132 - SOLUTION

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 8 6.7.6 Output Snubber Board .

Strona 133

User Manual AMETEK Programmable Power BPS Series 80 5.2.6.5 START/VIEW TRANSIENT SEQUENCE sub menu Figure 5-15:START/VIEW TRANSIENT SEQUENCE S

Strona 134

User Manual AMETEK Programmable Power BPS Series 81 SAVE REGISTER Save present instrument setup to a register number selected by the user. The

Strona 135 - 8.5 Factory Assistance

User Manual AMETEK Programmable Power BPS Series 82 5.2.8 UTILITY Menus Figure 5-17: UTILITY Menus The UTILITY menus provide access to less

Strona 136 - 8.6 Fuses

User Manual AMETEK Programmable Power BPS Series 83 UTILITY 2 CONFIGURATION The Configuration menu shows the installed options. This screen is

Strona 137 - 8.7 Firmware Updates

User Manual AMETEK Programmable Power BPS Series 84 ELAPSED TIME The elapsed time screen, when selected from the UTILITY menu, will appear for

Strona 138

User Manual AMETEK Programmable Power BPS Series 85 5.2.8.1 GPIB/RS232 (incl. USB/LAN) SETUP menu Figure 5-18: GPIB/RS232 SETUP Menu The GPIB/

Strona 139

User Manual AMETEK Programmable Power BPS Series 86 5.2.8.2 VOLTAGE/CURRENT CONTROL SETUP menu Figure 5-19: VOLTAGE/CURRENT CONTROL SETUP Menu

Strona 140 - Top Assembly 7003-427

User Manual AMETEK Programmable Power BPS Series 87 5.2.8.3 INITIAL SETUP menu Figure 5-20: INITIAL SETUP Menus Any time the power source i

Strona 141

User Manual AMETEK Programmable Power BPS Series 88 WAVE GROUP Sets the user defined waveform group that will be loaded at power on. Available

Strona 142

User Manual AMETEK Programmable Power BPS Series 89 5.2.8.4 LIMIT SETUP screen Figure 5-21: LIMIT SETUP Menu The limit setup screen is not a m

Strona 143 - Models

AMETEK Programmable Power BPS Series User Manual M440077-01 Rev A 9 List of Figures Figure 2-1: S

Strona 144

User Manual AMETEK Programmable Power BPS Series 90 5.2.8.5 CONFIGURATION SETUP screens Figure 5-22: CONFIGURATION SETUP Menus The confi

Strona 145 - 11. Options

User Manual AMETEK Programmable Power BPS Series 91 If this field is set incorrectly, the current limit scaling and current measurement will b

Strona 146 - 12. Error Messages

User Manual AMETEK Programmable Power BPS Series 92 5.2.10 OUTPUT CAL FACTORS Menu Figure 5-24: OUTPUT CAL FACTORS Menu (Series II only) The O

Strona 147 - BPS Series 147

User Manual AMETEK Programmable Power BPS Series 93 5.3 Output Programming 5.3.1 Set the Output Output parameters are all set from the PROGRAM

Strona 148 - BPS Series 148

User Manual AMETEK Programmable Power BPS Series 94 To change the output voltage: CounterClockwiseClockwiseINCRDECR 1. Press the SET key 2. P

Strona 149 - BPS Series 149

User Manual AMETEK Programmable Power BPS Series 95 Mode AC DC POWER Real power power MEASUREMENTS 2 VA POWER Apparent power power PEAK

Strona 150 - BPS Series 150

User Manual AMETEK Programmable Power BPS Series 96 5.4.2 Controller Measurements For BPS Series the following four measurement screens are ava

Strona 151

User Manual AMETEK Programmable Power BPS Series 97 load currents. When powering low power loads, measurement inaccuracies on rms and peak curre

Strona 152

User Manual AMETEK Programmable Power BPS Series 98 When selecting this trigger source, the field below the TRIG SOURCE field changed to “TRIG

Strona 153

User Manual AMETEK Programmable Power BPS Series 99 This mode is appropriate for capturing the inrush current of a load by programming the vol

Komentarze do niniejszej Instrukcji

Brak uwag