Podsumowanie treści

Strona 1 - Power Supplies

TM-GP6H-01XN Rev B www.programmablepower.com Internal GPIB Interface for XT/HPD Series Programmable DC Power Supplies Operation Manual GPIB-XT GPI

Strona 2

About This Manualviii Operating Manual for GPIB for XT/HPD Series Power Supply

Strona 3

ixContentsAbout This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiSection 1.Feature

Strona 4

Contentsx Operating Manual for GPIB for XT/HPD Series Power SupplyDiagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 5 - SAFETY SYMBOLS

11Section 1. Features and SpecificationsDescriptionThe internal GPIB interface card allows you to operate your power supply from a computer controller

Strona 6

Features and SpecificationsFeatures and Functions12 Operating Manual for GPIB for XT/HPD Series Power SupplyFeatures and FunctionsFeatures • 16-bit p

Strona 7

Features and SpecificationsSpecifications13SpecificationsThe specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All

Strona 8

Features and SpecificationsSpecifications14 Operating Manual for GPIB for XT/HPD Series Power SupplyTable 1.2 Specifications for HPD 300 W Series Sup

Strona 9

15Section 2. Installation and ConfigurationIntroductionTo use this product, you must have the following equipment:• a compatible model of DC output po

Strona 10 - About This Manual

Installation and ConfigurationInitial Inspection16 Operating Manual for GPIB for XT/HPD Series Power SupplyFigure 2.1 Power Supply Front Panel with G

Strona 11 - Contents

Installation and ConfigurationInitial Inspection17Figure 2.3 GPIB Interface PCBJUMPER SELECTIONJ217 Local OVP control selection [closed] [default]. Se

Strona 13 - Description

Installation and ConfigurationBasic Setup Procedure18 Operating Manual for GPIB for XT/HPD Series Power SupplyBasic Setup ProcedureThis procedure can

Strona 14 - Features and Functions

Installation and ConfigurationOVP Selection19OVP SelectionOver voltage protection (OVP) on the GPIB Interface is set at the factory for remote softwar

Strona 15 - Specifications

Installation and ConfigurationIEEE-488 Primary Address Selection20 Operating Manual for GPIB for XT/HPD Series Power SupplyIEEE-488 Primary Address S

Strona 16 - 10 volts

Installation and ConfigurationRemote/Local Operation21Remote/Local OperationYou can enable or disable remote or local operation of your power supply i

Strona 17

Installation and ConfigurationRemote/Local Operation22 Operating Manual for GPIB for XT/HPD Series Power SupplyTable 2.4 Remote Mode Power On Conditi

Strona 18 - Initial Inspection

Installation and ConfigurationRemote/Local Operation23Local ModeDisableJumper J95You can disable local control of the power supply by removing jumper

Strona 19 - Figure 2.3 GPIB Interface PCB

Installation and ConfigurationRemote/Local Operation24 Operating Manual for GPIB for XT/HPD Series Power SupplyPower OnServiceRequest(PON SRQ)Setting

Strona 20 - Basic Setup Procedure

Installation and ConfigurationUser Signals25User SignalsConnector J7User SignalsAuxiliary connector J7, located on the GPIB interface rear panel, prov

Strona 21 - OVP Selection

Installation and ConfigurationUser Signals26 Operating Manual for GPIB for XT/HPD Series Power SupplyFigure 2.5 J7 User Signal Connector Circuit Bloc

Strona 22

Installation and ConfigurationUser Signals27Figure 2.6 J7 User Cable with Ferrite BlockJ7 User CableFerrite BlockTo User Custom InterfaceTo J7 Connect

Strona 23 - Remote/Local Operation

About AMETEK AMETEK Programmable Power, Inc., a Division of AMETEK, Inc., is a global leader in the design and manufacture of precision, programmable

Strona 24

Installation and ConfigurationUser Signals28 Operating Manual for GPIB for XT/HPD Series Power Supply

Strona 25

29Section 3. OperationIntroductionThis section covers GPIB interface programming, starting with IEEE-488 functions, continuing with an extensive set o

Strona 26

OperationGPIB Operation30 Operating Manual for GPIB for XT/HPD Series Power SupplyTable 3.1 IEEE-488.1 Interface Functions ImplementedMultilineContro

Strona 27 - User Signals

OperationGPIB Operation31DeviceTriggerDevice Trigger will implement the most recently programmed values whether the unit is in local or remote control

Strona 28

OperationGPIB Operation32 Operating Manual for GPIB for XT/HPD Series Power SupplySerial Poll In a serial poll, the controller polls each device.Exam

Strona 29 - Ferrite Block

OperationCommand Syntax33Command SyntaxManualConventionsThe manual uses these conventions when displaying command information. These characters are no

Strona 30

OperationCommand Syntax34 Operating Manual for GPIB for XT/HPD Series Power SupplyCommandFormat andParametersThe device-dependent language for the GP

Strona 31 - Section 3. Operation

OperationCommand Syntax35Table 3.3 Command ParametersFloating Point Number <float> Variables sent with command parameters are floating point num

Strona 32

OperationCommand Syntax36 Operating Manual for GPIB for XT/HPD Series Power SupplyCommandStringsIf you send more than one command line, separate the

Strona 33 - GPIB Operation

OperationCommand Summary37Command SummaryUse these commands to control the operation of the supply. They are listed here by function: PROGRAMMING, QUE

Strona 34

This page intentionally left blank. ii

Strona 35 - Command Syntax

OperationCommand Summary38 Operating Manual for GPIB for XT/HPD Series Power SupplyTable 3.6 Query CommandsCommand DescriptionAUXA? Asks for the stat

Strona 36

OperationCommand Summary39Table 3.7 Calibration CommandsTable 3.8 Status CommandsCommand DescriptionCMODE Places the supply into calibration mode.IDAT

Strona 37 - Table 3.3 Command Parameters

OperationCommand Reference40 Operating Manual for GPIB for XT/HPD Series Power SupplyCommand ReferenceTable 3.9 Command ReferenceCommand DescriptionA

Strona 38 - Format:

OperationCommand Reference41Command DescriptionDLY <seconds> Sets a programmable time delay employed by the supply before reporting fault condit

Strona 39 - Command Summary

OperationCommand Reference42 Operating Manual for GPIB for XT/HPD Series Power SupplyCommand DescriptionFOLD? Returns the supply’s present foldback

Strona 40 - Table 3.6 Query Commands

OperationCommand Reference43Command DescriptionIRDAT <Ilo>,<Ihi> Calculates and records the slope and offset for readback voltage using IR

Strona 41 - Table 3.8 Status Commands

OperationCommand Reference44 Operating Manual for GPIB for XT/HPD Series Power SupplyCommand DescriptionOUT <1/ON>,<0/OFF> Enables or dis

Strona 42 - Command Reference

OperationCommand Reference45Command DescriptionSRQ <1/ON>,<0/OFF> SRQ ON enables the supply to respond to a variety of fault conditions wi

Strona 43 - “Error Codes” on page 49

OperationCommand Reference46 Operating Manual for GPIB for XT/HPD Series Power SupplyCommand DescriptionVDATA <Vlo>,<Vhi> Calculates and

Strona 44

OperationCommand Reference47Command DescriptionVRLO The power supply outputs a voltage value to an external voltmeter connected as part of the calibra

Strona 45 - “Accumulated Status

Important Safety Instructions Before applying power to the system, verify that your product is configured properly for your particular application.

Strona 46

OperationAccumulated Status, Status, and Fault Registers48 Operating Manual for GPIB for XT/HPD Series Power SupplyAccumulated Status, Status, and Fa

Strona 47

OperationError Codes49Error CodesIf the ERR flag in the accumulated status or fault registers has been activated, an ERR? query will return an error n

Strona 48

OperationTroubleshooting50 Operating Manual for GPIB for XT/HPD Series Power SupplyTroubleshootingDiagnosticLEDsThis section describes the diagnostic

Strona 49

51Section 4. CalibrationIntroductionYou can calibrate the GPIB interface by adjusting the signal levels on the interface card so that they correspond

Strona 50 - Example:

CalibrationVoltage Mode Calibration52 Operating Manual for GPIB for XT/HPD Series Power SupplyVoltage Mode CalibrationVoltageCalibrationSetup1. Disco

Strona 51 - Error Codes

CalibrationVoltage Mode Calibration53VoltageReadbackCalibrationProcedure1. Set the power supply for calibration as in Figure 4.1.2. Activate calibrati

Strona 52 - Troubleshooting

CalibrationCurrent Mode Calibration54 Operating Manual for GPIB for XT/HPD Series Power SupplyCurrent Mode CalibrationCurrentCalibrationSetup1. Disco

Strona 53 - Section 4. Calibration

CalibrationCurrent Mode Calibration55CurrentReadbackCalibrationProcedure1. Connect the current shunt and voltmeter to the power supply as shown in Fi

Strona 54 - Voltage Mode Calibration

CalibrationOver Voltage Protection (OVP) Calibration56 Operating Manual for GPIB for XT/HPD Series Power SupplyOver Voltage Protection (OVP) Calibrat

Strona 55

This page intentionally left blank. iv

Strona 56 - Current Mode Calibration

Product Family: Internal GPIB Interface for XT/HPD Series Programmable DC Power Supplies Warranty Period: Five Years WARRANTY TERMS AMETEK Programmab

Strona 57

This page intentionally left blank. vi

Strona 58

viiAbout This ManualThis technical manual is for the internal GPIB interface, a microprocessor-controlled option card for XT and HPD Series DC output