Isolated Analog Programmer Operation DLM-E Series and DCS-E Series
2-6 M51A Option
Auxiliary Sources
AUXILIARY DC OUTPUT: Pin-15, 16VDC source for use with logic and programming circuits.
Source capability is adequate to provide for full scale programming of output voltage, current, or
OVP when the user connects it to the appropriate programming input(s). Source is referenced
to Pin-6. Can be used as a source for 4-20mA programming current.
AUXILIARY DC RETURN: Pin-6, return for AUXILIARY source output.
4-20MA CURRENT PROGRAMMING OFFSET SIGNAL (-2.5VDC): Pin-8, provides a negative
2.5VDC to zero out the 4mA signal generated by internal circuits when using 4-20mA
programming of output voltage. Jumpers to Pin-20.
4-20MA CURRENT PROGRAMMING OFFSET SIGNAL (-2.5VDC): Pin-11, provides a
negative 2.5VDC to offset the signal generated by internal circuits when using 4-20mA
programming of output current. Jumpers to Pin-23.