Installation and Programming Manual
12
Chapter 3: Mounting and Wiring
13
Installation and Programming Manual
Chapter 3: Mounting and Wiring
Figure 3-4 Relay Output Pinout Diagram
Figure 3-5 Power Supply Pinout Diagram
Power Supply Module (FMPS01)
The power supply module has a main power input, an auxiliary input, and a fault check output.
(See Figure 3-5). Power input: 85-265 VAC at 450 mA maximum. Fault check output: 8 amps
250 VAC, 30 VDC, 1/4 HP 125, 250 VAC. It is recommended that the fault check contacts be
connected to the required safety interlock for the press. Auxiliary input: 85-265 VAC at 12 mA
maximum. The terminal wire size for all connectors is No. 22-12 AWG. See page 3, 35, 36 and
37 for use of this special purpose input, concerning position hold and move detection.
T13692 chapter 3.indd 3/17/04, 6:31 AM13