Installation and Programming Manual
42
Chapter 4: Programming
43
Installation and Programming Manual
Chapter 4: Programming
Error Condition Output State (203)
This function allows you to select how the digital outputs will react to a failure in the encoder
module, transducer and/or cable. The following three options describe what will happen on a
failure.
1. Select the function key.
The monitor displays “F-----”
2. Enter function 203. Select the enter key.
The monitor displays the function’s current value.
3. Enter either 0, 1 or 2.
0 = All Outputs Off (default)
1 = All Outputs On
2 = Last Valid Position
Select the enter key.
0, 1 or 2
203
Enter either
8
(F)
8
T13692 Chapter 4.indd 3/17/04, 6:50 AM43