SG Series Programming Ethernet Features, Functions and Specifications
M550129-03 Rev K
4-5
4.3.6
Readback Accuracy
SGA SGI
Voltage ± (0.1% of full scale output voltage)
± (0.1% + 0.15% of
maximum output voltage)
Current*
± (0.25% of full scale output current)
*
± (0.1% + 0.4% of
maximum output current)
*
After 30 minutes operation with fixed line, load, and temperature.
Note: Refer to the applicable power supply manual (SGA or SGI) for effects
of line regulation, load regulation, and temperature on accuracy
specifications.