SCPI Command Operation SG Series Programming
6-24 M550129-03 Rev K
Command
Description
SCPI
:TERM
<NRf>
Sets the return string terminators to be used by the device. Factory
set to 3. The valid range is 1-4. Values indicate the following
terminator(s):
1 = 0x0d only (CR), 2 = 0x0a only (LF), 3 = 0x0d 0x0a (CR LF), 4 =
0x0a 0x0d (LF CR)
N
:TERM?
Returns the string terminators to be used by the device. N
:VERsion?
Returns a numeric value corresponding to the SCPI version number
for which the instrument complies. The response is in the format
YYYY.V where the Y’s represent the year and V represents the
approved version number for that year (e.g., 1995.0)
C
Table 6-6 Table 6-7. System Fault Registers
Bit Position
Bit Weight
Fault1
8
Fault9
16
Fault17
24
Fault25
31
7 128 Channel 1 not used not used not used
6 64 not used not used not used not used
5 32 not used not used not used not used
4 16 not used not used not used not used
3 8 not used not used not used not used
2 4 not used not used not used not used
1 2 not used not used not used not used
0 1 not used not used not used not used
The SYStem:FAULt? query returns 4 numeric values separated by commas.
Each value is the decimal equivalent of the total bit weights for that System Fault
Register as described in the table above.