Sorensen SF Series IEEE 488.2 and SCPI Command Operation
3.9
3.9.1
3.9.2
SYSTEM SCPI Command Subsystem
SYSTEM SCPI Command Summary
SYSTem
:ERRor?
:FAULt?
:VERsion?
:LOCAL <boolean>
:LOCAL?
:LOCLOUT <boolean>
SYSTEM SCPI Command Reference
In the following table a "C" in the SCPI column indicates that the command is SCPI-compliant.
The Q? column indicates whether the command can also be used for querying.
Command Description SCPI Q?
SYSTem
System subsystem. C
:ERRor?
Queries Error Queue for next error/event entry
(first in, first out). Entries contain an error
number and descriptive text. A 0 return value
indicates no error occurred; negative numbers
are reserved by SCPI. The maximum return
string length is 255 characters. The queue
holds up to 10 error/entries. All entries are
cleared by the *CLS command.
C
:FAULt?
Returns four numeric values separated by
commas for the four system fault registers. See
System Fault Registers below. Valid response
is 128, 0, 0, 0 or 0, 0, 0, 0.
Response: <Fault1–8>, <Fault9–16>,
<Fault17–24>, <Fault25–31>
N
:VERsion?
Returns a numeric value corresponding to the
SCPI version number for which the instrument
complies. The response is in the format
YYYY.V where the Y’s represent the year and
V represents the approved version number for
that year (e.g., 1995.0)
C
M550292-03 (Programming) 3-17