Features, Functions, and Specifications Sorensen SF Series
1-2 M550292-03 (Programming)
Readback Functions
• Actual measured voltage and current
• Current settings
• Soft current limit
• Status and Accumulated Status registers
• Programming error codes
• Fault codes
• Manufacturer, power supply model, and firmware version identification
1.3 Specifications
Programming Resolution
Current: 0.002% of full scale
Programming Accuracy
Current: ± ( 0.4% of maximum output current)*
Readback Resolution
Voltage: ± 0.002% of full scale
Current: ± 0.002% of full scale
Readback Accuracy
Voltage: ± ( 0.15% of full scale output voltage)
Current: ± ( 0.4% of full scale output current)*
* After 30 minutes operation with fixed line, load, and temperature.
Note: Refer to the SFA or SFI power supply Operation manual for effects of line regulation,
load regulation, and temperature on accuracy specifications.
Specifications subject to change without notice.