M380056-03 Rev M 111
5.
LOAD MODULE REMOTE
PROGRAMMING
5.1
INTRODUCTION
This section covers the remote programming option for the ReFlex Power™
Active Load Module. This interface enables operation of the Load from a
computer via the Ethernet, allowing full remote programming control and
monitoring of the Load module.
The syntax of all SCPI commands implemented by the ReFlex Power™ system
and documented in this manual, are either SCPI confirmed in the SCPI 1999.0
Specification, Volume 2: Command Reference, or they are customized
commands not part of the SCPI definition but conform to SCPI syntax.
5.2
FEATURES AND FUNCTIONS
F
EATURES
16-bit programming and 16-bit readback of voltage and current and
resistance
Programmable over voltage, over current and over power protection
SCPI compliant command set
User selectable Constant Resistance or Constant Current mode
Field-upgradeable firmware via Ethernet
Soft calibration
P
ROGRAMMABLE
F
UNCTIONS
Input current and resistance
Soft limits for voltage, power and current
Over voltage protection
Input enable/disable
Maskable fault interrupt