AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
112 Manual P/N 7003-961 Rev AA
VOLTage:SLEW:MODE
Phase Selectable
This command determines how the output voltage slew rate is controlled during a triggered
output transient. The choices are:
FIXed The slew rate is unaffected by a triggered output transient.
STEP The slew rate is programmed to the value set by
VOLTage:SLEW:TRIGgered when a triggered transient occurs.
PULSe The slew rate is changed to the value set by VOLTage:SLEW:TRIGgered
for a duration determined by the pulse commands.
LIST The slew rate is controlled by the voltage slew list when a triggered transient
occurs.
Command Syntax [SOURce:]VOLTage:SLEW:MODE<mode>
Parameters FIXed | STEP | PULSe | LIST
*RST Value FIX
Examples VOLT:SLEW:MODE LIST VOLT:SLEW:MODE FIX
Query Syntax [SOURce:]VOLTage:SLEW:MODE?
Returned Parameters <CRD>
Related Commands VOLT:SLEW:TRG VOLT:SLEW
VOLTage:SLEW:TRIGgered
Phase Selectable
This command selects the slew rate that will be set during a triggered step or pulse
transient. A parameter of MAXimum will set the slew to its maximum possible rate. The
maximum allowed value is1E9.
Command Syntax [SOURce:]VOLTage:SLEW:TRIGgered<NRf+>
Parameters 0 to 1E9 | MAXimum
Unit V/S (volts per second)
*RST Value MAXimum
Examples VOLT:SLEW:TRIG 1 VOLT:SLEW:TRIG MAX
Query Syntax [SOURce:]VOLTage:SLEW:TRIGgered?
Returned Parameters <NR2>
Related Commands VOLT:SLEW:MODE VOLT:SLEW