AMETEK Programmable Power BPS / MX / RS Series SCPI Programming Manual
78 Manual P/N 7003-961 Rev AA
4.11.5 Programmable Impedance [MX15-1Pi/MX30-3Pi/MX45-3Pi/RS Only]
OUTPut:IMPedance[:STATe] [MX15-1Pi / MX30-3Pi / MX45-3Pi / RS Series Only]
Phase Selectable
This command enables or disables the source output impedance programming. The state of
a disabled output impedance is equivalent to the minimum impedance. The query form
returns the output state.
Command Syntax OUTPut:IMPdance[:STATe]<bool>
Parameters 0 | OFF | 1 | ON
*RST Value OFF
Examples OUTP:IMP 1 OUTP:IMP:STAT ON
Query Syntax OUTPut:IMPdeance[:STATe]?
Returned Parameters 0 | 1
Related Commands OUTPut:IMPedance:REAL OUTput:IMPedance:REACtive
OUTPut:IMPedance:REAL [MX15-1Pi / MX30-3Pi / MX45-3Pi / RS Series Only]
Phase Selectable
This command sets the real part of the output impedance of the AC source in mili-ohms.
OUTPut:IMPedance:STATe must be enabled for the programmed impedance to affect the
output.
Command Syntax OUTP:IMPedance:REAL<NRf>
Parameters min to 200
*RST Value min
Examples OUTP:IMP:REAL 200
Query Syntax OUTPut:IMP:REAL?
Returned Parameters <NR2>
Related Commands OUTP:IMP OUTP:IMP:REAC
OUTPut:IMPedance:REACtive [MX15-1Pi / MX30-3Pi / MX45-3Pi / RS Series Only]
Phase Selectable
This command sets the reactive part of the output impedance of the AC source in micro
Henry. OUTPut:IMPedance:STATe must be enabled for the programmed impedance to
affect the output.
Command Syntax OUTP:IMP:REACtive<NRf>
Parameters min to 220 (uHenrys)
*RST Value min
Examples OUTP:IMP:REAC 150
Query Syntax OUTPut:IMP:REACtive?
Returned Parameters <NR2>
Related Commands OUTP:IMP OUTP:IMP:REAL