IEC411:DIPS:ANGLe
This command sets the start phase angle for the dips.
Command Syntax IEC411:DIPS:ANGLe
Parameters <numeric>
Examples IEC411:DIPS:ANGL 90
Query Syntax IEC411:DIPS:ANGL?
Returned Parameters <NR2>
IEC411:STATe
This command will enable the IEC411 option and initialize the associated data.
Command Syntax IEC411:STATe <state>
Parameters <ON|OFF>
Examples IEC411:STAT ON
Query Syntax IEC411:STAT?
Returned Parameters <boolean>
IEC411:VARiants:RUN[:ALL]
This command will cause the variants automated test sequence by the standard to run.
Refer to Table 14 in the User Manual.
Command Syntax IEC411: VARiants:RUN[:ALL]
Parameters <none>
Examples IEC411:VAR:RUN
Query Syntax none
Returned Parameters <none>
IEC411: VARiants:RUN:SINGle
This command will run a single variant test once. The test is defined by the variants
parameters voltage, cycle and angle.
Command Syntax IEC411:VARiants:RUN:SINGle
Parameters <none>
Examples IEC411:VAR:RUN:SING
Query Syntax none
Returned Parameters <none>