Programming Manual Lx \ Ls Series II
110
Command Syntax SYSTem:REMotel
Parameters None
Example SYST:REM
Related Commands SYST:LOC SYST:RWL
SYSTem:RWLock
This command can only be used with the RS-232 interface. It locks out the Local key on the front
panel. The SYST:LOC command must be used to unlock the front panel. For GPIB, use the Local
Lockout bus message.
Command Syntax SYSTem:RWLock
Parameters None
Example SYST:RWL
Related Commands SYST:LOC
SYSTem:TEMPerature?
This command will return the internal ambient temperature of the power source in degrees
Celsius.
Command Syntax SYSTem:TEMPerature?
Parameters none
Example SYST:TEMP?
SYSTem:VERSion?
This query returns the SCPI version number to which the AC source complies. The returned value
is of the form YYYY.V, where YYYY represents the year and V is the revision number for that
year.
Query Syntax SYSTem:VERSion?
Parameters None
Returned Parameters <NR2>
Example SYST:VERS?