DO160:ABNormal:FREQuency:TRANsient
This command applies to Group 1 only for the EuroCAE standard. Refer to the User Manual for
details.
Command Syntax DO160:ABNormal:FREQuency:TRANsient
Parameters none
Examples DO160:ABN:FREQ:TRAN
Query Syntax none
Returned Parameters none
8.4.5 DO160 Test Setup Commands
DO160:STANdard
This command will select the proper test standard. The standard selection must be set prior to
any test selection.
The RTCA2 selection includes the Change 2 notice to the DO160D test standard as it applies to
section 16. The RTCA selection does not include the Change 2 updates.
The Airbus standard is the same as the EuroCAE-14D standard with the exception of nominal
voltage modulation.
Command Syntax DO160:STANdard
Parameters RTCA | RTCA2 | EURocae | AIRBus
Examples DO160:STAN RTCA
Query Syntax DO160:STAN?
DO160:GROup
This command is used to select equipment Group 1, 2 or 3 for the EUROCAE standard or
equipment Group ACF, ANF or AWF for the RTCA2 standard. Some test (commands) apply only
to specific groups of equipment. If a test is executed for a group to which it does not apply, the
command is ignored by the power source. Note that in this case no error is generated. The
application program is responsible for selecting the relevant Standard, Group and test.
Command Syntax DO160:GROup <NR1>
Parameters 1 | 2 | 3 | ACF | ANF | AWF
Examples DO160:GROup 2
Query Syntax DO160:GRO?