Programming Manual Lx \ Ls Series II
67
4.14 Power On Subsystem
This subsystem controls the specific configuration settings at power on. Most power on settings
are determined by the power on register recall state using the OUTPut:PON:STATe command.
Some aspects are not part of a register however and must be controlled using the PONS
commands.
Subsystem Syntax
[SOURce:]PONSetup
:CLOCk STD | MAST | AUX
:PEAK:CURRent[:PROTection] Disables peak current protection.
:RELay:HOLD Sets output off relay open delay in seconds.
:SYNChronize[:SOURce] EXTernal | LINE
PONSetup:CLOCk
This command is used to set the clock and lock mode at power up. It is factory set and should not
be changed unless the configuration has been modified in the field. Units with the –LKM option
are fixed to MAST mode. Units with the –LKS option can be set to either STANdalone or AUX.
When set to AUX, the –LKS unit will power up in external clock mode. When set to STANDalone,
the –LKS unit will power up in internal clock mode. The –LKM unit always powers up in internal
clock mode. It‟s clock state cannot be changed.
Command Syntax PONSetup:CLOCk
Parameters STANdalone | MASTer | AUXiliary
Examples PONS:CLOC
Query Syntax PONS:CLOC?
Returned Parameters <CRD>
Related Commands None
PONSetup:PEAK:CURRent[:PROTection]
This command can be used to disable the peak current shutdown mode. It is factory disabled and
should be left disabled for most situations. This command is not available on the
HP6834B/CI4500iL.
Command Syntax PONSetup:PEAK:CURRent[:PROTection]
Parameters 0 | 1 | OFF | ON
Examples PONS:PEAK:CURR 1
Query Syntax PONS:PEAK:CURR?
Returned Parameters 0 | 1
Related Commands OUTP:PROT:DEL
PONSetup:SYNChronize[:SOURce]
This command can be used to set the initial sync mode between External Sync or Line Sync. This
requires the –EXT or –LNS option respectively. This command is supported in firmware revision
1.50 and higher.
Command Syntax PONSetup:SYNChronize:[:SOURce]
Parameters EXTernal | LINE
Examples PONS:SYNC:SOUR EXT
Query Syntax PONS:SYNC:SOUR?
Returned Parameters <CRD>
Related Commands FREQuency:MODE SENSe